5/5 - (1 vote)

Exam Dumps D-PE-OE-23 Practice Free Latest EMC Practice Tests

D-PE-OE-23 Exam Questions | Real D-PE-OE-23 Practice Dumps

EMC D-PE-OE-23 Exam Syllabus Topics:

Topic Details
Topic 1
  • Server Portfolio and Features: This section of the exam measures the skills of Dell System Administrators and Dell Technical Support Engineers and covers the definitions of chassis form factors and their numbering systems.
Topic 2
  • Server Components: This section of the exam measures the skills of Dell System Administrators and covers various server components, including processors, memory options, and configurations. It also addresses power options, redundancy features, thermal management, and liquid cooling systems.
Topic 3
  • System Administration: This section of the exam measures the skills of Dell System Administrators and covers verifying health status and managing iDRAC licenses.
Topic 4
  • Server Management and Configuration Tools: This section of the exam measures the skills of Dell Technical Support Engineers and covers the functions of iDRAC, including login procedures and connection methods. It explains various management interface options like LCC and racadm, as well as in-band and out-of-band management techniques.
Topic 5
  • Server Troubleshooting: This section of the exam measures the skills of Dell Technical Support Engineers and covers analyzing visual indicators on server components such as system IDs and power supply units.

 

Q21. A system board has been replaced on a Dell PowerEdge 16G server. What data can Easy Restore recover?

 
 
 
 

Q22. A technician configures a server then loads Windows 2016. The server then goes through testing.
Before the servers go live the technician asks another technician who has limited experience with servers to quickly check the settings to ensure that everything is operational.
The next day the server is rebooted and the operating system fails to load. No errors are displayed and the boot sequence is correct. Errors are found in the log entries.
What should be done to resolve this issue in the least amount of time?

 
 
 
 

Q23. What is the correct order of steps taken during the BIOS/UEFI Recovery process?

Q24. When does configuration validation run?

 
 
 
 

Q25. A technician has a server with the following memory configuration:
– Sixteen 4 GB dual-rank DIMMs
– 8 GB available to the OS
The workload intended for the server required the memory configuration to protect against some errors.
Now the technician must deploy for a different workload that requires access to all available memory.
Which setting should the technician change to make all memory available to the system?

 
 
 
 

Q26. Where is the data stored to allow Easy Restore to successfully complete a system board replacement?

 
 
 
 

Q27. What is a characteristic of SupportAssist Enterprise on Dell EMC PowerEdge 14G servers?

 
 
 
 

Q28. An administrator is in a non-secure location with a high latency connection. What option should be used to recover a PowerEdge server using an existing server profile?

 
 
 
 

Q29. What is a key feature of Part Replacement in Lifecycle Controller?

 
 
 
 

Q30. What is the prerequisite for using BIOS Live Scanning?

 
 
 
 

Q31. What is a systems management console solution optimized for monitoring and managing Dell enterprise and remote office hardware?

 
 
 
 

Q32. A technician wants to configure the iDRAC on a new server using the iDRAC Quick Sync 2 feature.
What is required to use this feature?

 
 
 
 

Q33. A company has an environment with multiple AD forests in a one-way trust relationship. The AD provider on the cluster is configured with SFU.
The trusted domains are failing to supply UIDs and GIDs to the Dell EMC Isilon cluster. As a result, users from the trusted domain are receiving an “access denied” error message.
What is a possible reason for the denial?

 
 
 
 

Q34. Case Study 3
A financial services company has file sharing workflows and 2000 home directories which include 70% Microsoft Windows and 30% Linux. The Security team is also interested in credit card usage data analytics such as point of sale, geolocation, and authorization and transaction data. Home directories and file shares do not require D@RE or SEC compliance.
However, due to the sensitivity of the credit card data, the company requires D@RE for credit card information and must adhere to the U.S. SEC 17a-4(f) compliance standards. Additionally, they are interested in auditing user access and anti-virus features.
The compute and storage environment consists of the following:
– 200 TB of Fibre Channel drives on NetApp ONTAP 7
– Environment is expected to grow 200 TB over the next three years
Which combined solution addresses the company’s requirement for D@RE and U.S.SEC 17a-4(f)?

 
 
 
 

Q35. Which mobile devices are supported by Quick Sync 2.0 in 14G PowerEdge servers?

 
 
 
 

Q36. A technician is updating firmware on a Windows Server using the Lifecycle Controller following a NIC replacement, but it fails to complete the update on the NIC despite successfully updating other components.
The update’s read me confirms that the current version is too old to upgrade with the Lifecycle Controller and an alternative method must be used.
Which three update methods could the technician use to meet this requirement? (Choose three.)

 
 
 
 
 

Q37. A technician is setting up a previously used server. Upon power up, the PERC alerts them to the presence of a foreign configuration. In the iDRAC storage section, the technician checks Foreign View.
The foreign array configuration is the same as the configuration needed for the new project.
What is a recommended way to prepare the disks for the new project?

 
 
 
 

Q38. A server is equipped with 2 CPUs and 12x 8 GB DIMMs, for a total of 96 GB. The OS is not seeing all the memory.
Which memory mode should be configured so that all memory is seen by the OS?

 
 
 
 

Q39. A technician resets the iDRAC but when they attempt to log back in to the iDRAC is offline.
Why is the iDRAC offline?

 
 
 
 

Q40. A system administrator is trying to connect with a mobile device to a Dell PowerEdge 16G server using Quick Sync 2. They failed to make a connection.
What is the reason for the failure?

 
 
 
 

Q41. SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens. When displaying a question, you can easily review the related case study by clicking on the ‘Review Case Study’ icon shown below:
Case Study 5 – Refer to the Exhibit.

Backing up data from a Dell EMC Isilon cluster exceeds the company’s backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes.
Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC Net Worker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company’s IT team is now looking for a method to increase the performance of their backups. After some investigations, you notice that the backup job quiesces the file system. This is creating lock contention issues on open files and not allowing users full access to data when the backup job runs.
What advice should be provided to the team to eliminate lock contention and allow full access to users?

 
 
 
 

Q42. Refer to the exhibit.

A technician it installing an OS to a server. The OS array is 2.8TBs. The OS install is unable to start.
What should the technician do to install the OS?

 
 
 
 

Q43. A technician is ready to deploy a server. If a critical part such as the system board fails, they must be able to replace the system board, reconfigure components, and update the firmware revisions in the fastest possible time.
How should the technician meet this requirement?

 
 
 
 

Q44. On a PowerEdge R640 server, the System Lockdown mode has been enabled. Certain features are no longer available in the System BIOS utility or IDRAC GUI.
Which other feature is no longer available?

 
 
 
 

Verified D-PE-OE-23 Exam Dumps Q&As – Provide D-PE-OE-23 with Correct Answers: https://www.surepassexams.com/D-PE-OE-23-exam-bootcamp.html

         

Related Links: myportal.utt.edu.tt myportal.utt.edu.tt divisionmidway.org www.stes.tyc.edu.tw myportal.utt.edu.tt myportal.utt.edu.tt

Leave a Reply

Your email address will not be published. Required fields are marked *

Enter the text from the image below